PCB Trace Width Calculator

IPC-2221 trace sizing: current, copper weight and allowed temperature rise → the minimum trace width for external and internal layers, plus the trace's resistance and voltage drop.

Trace layer

Trace and current

e.g. 1, 0.5 or 10 - read in the selected unit.

Copper weight - 1 for 1 oz/ft2 (35 um), 2 for 2 oz/ft2, or a mil thickness like 1, 2 or 35 - read in the selected unit.

Allowed temperature rise above ambient, e.g. 5, 10 or 20 - enter degrees Celsius only.

e.g. 10, 100 or 25.4 - read in the selected unit.

IPC-2221 sizing - the entered number is always read in the selected unit; switching a unit reinterprets the same number, it never rewrites it. Internal copper is buried in board material, so it needs roughly 2.6x the width of external for the same current and temperature rise - both widths are always shown.

Minimum trace width

Display only - mil, mm or inches; the calculation is unchanged.

Enter the trace current, copper weight and allowed temperature rise - the IPC-2221 minimum width appears here. Pick external or internal layer; add an optional trace length for resistance and voltage drop.

Before you rely on this

  • IPC-2221 (the IPC-2221A generic chart) is the older, conservative standard - IPC-2152 is newer and usually allows narrower traces for the same current and temperature rise, so results err wide rather than narrow; it is a sizing estimate, not a thermal guarantee.
  • Not an impedance tool - characteristic impedance, controlled-Z microstrip/stripline and RF behaviour are a different calculation and are not modelled.
  • DC or slowly-varying current only - AC skin effect, proximity effect and frequency-dependent losses are not modelled.
  • External and internal constants differ (k = 0.048 vs 0.024) - internal traces need roughly 2.6x the copper area at the same current and rise; both widths are always shown so the difference is visible.
  • Trace resistance and voltage drop use copper resistivity at 20 degC (1.72e-8 ohm m) and the minimum-width trace only - connectors, the return path, planes and hot-trace resistivity are not included.
  • Units come from the pickers - enter plain numbers; the entered number is always read in the selected unit.

Enter the current, copper weight and allowed temperature rise - pick the layer and optionally add a trace length.

Privacy settings

Checking…

We count anonymous tool use and coarse errors to improve ToolDeck. We do not send your files, pasted text, generated links, or results. Normal network delivery still exposes connection metadata to Cloudflare. Your choice is stored only in this browser's local storage — we do not create a visitor ID. Decline opts out; your browser's Global Privacy Control or Do Not Track signal overrides any choice.